| 101 |
Grid voltage beyond permitted limits |
Check grid voltage; ensure circuit breakers ON. If persists, contact Fronius Service Partner. |
| 102 |
AC voltage too high |
Check grid voltage and settings; if still occurring, contact Fronius Service Partner. |
| 103 |
AC voltage too low |
Check grid voltage; if persists contact Fronius Service Partner. |
| 104 |
Mains frequency beyond permitted limits |
Check grid frequency and service-menu values; if unresolved, contact Fronius Service Partner. |
| 105 |
AC frequency too high |
Contact original installer or Fronius Service Partner. |
| 106 |
AC frequency too low |
Contact original installer or Fronius Service Partner. |
| 107 |
AC grid outside allowed limits |
Contact installer or Fronius Service Partner. |
| 108 |
Independent (island) operation detected |
Contact installer / Fronius Service Partner. |
| 112 |
Residual Current Monitoring Unit (RCMU) error |
Contact installer / Fronius Service Partner. |
| 141 |
Grid frequency jump too high |
Contact installer / Fronius Service Partner. |
| 301 |
AC output over-current |
Usually auto-resolves; if continuous, restart system and if still persists contact Fronius Service Partner. |
| 302 |
DC input over-current |
Usually auto-resolves; if continuous, restart system and contact Fronius Service Partner. |
| 303 |
DC module or board overheating |
Ensure ventilation unobstructed; if persists contact Fronius Service Partner. |
| 304 |
AC module (heat-sink) overheating |
Ensure ventilation; if continues contact Fronius Service Partner. |
| 305 |
Power not fed in though relay is closed |
Usually auto-resolves; if persistent contact Fronius Service Partner. |
| 306 |
PV output too low to feed (morning/evening low sun) |
If occurs during sufficient sunlight, contact Fronius Service Partner. |
| 307 |
PV voltage too low to feed |
Same as above. |
| 308 |
Intermediate circuit over-voltage |
Usually auto-resolves; if persistent contact Fronius Service Partner. |
| 309 |
DC input voltage MPPT1 too high |
If recurring, contact Fronius Service Partner. |
| 313 |
DC input voltage MPPT2 too high |
If recurring, contact Fronius Service Partner. |
| 314 |
Current sensor calibration timeout |
Try restart; if persists contact Fronius Service Partner. |
| 315 |
AC current sensor error |
Contact installer / Fronius Service Partner. |
| 316 |
Interrupt check fail (internal) |
Contact installer / Fronius Service Partner. |
| 317 |
Unbalanced intermediate circuit voltage |
Contact Fronius Service Partner. |
| 318 |
DC back-current detected |
Contact installer / Fronius Service Partner. |
| 325 |
Connection area overheating |
Contact installer / Fronius Service Partner. |
| 326 |
Fan 1 error |
Contact installer / Fronius Service Partner. |
| 327 |
Fan 2 error |
Contact installer / Fronius Service Partner. |
| 401 |
No communication with power stage set |
If persists, contact Fronius Service Partner. |
| 406-407 |
Temperature sensor faults (AC/DC) |
Contact Fronius Service Partner. |
| 408 |
DC component detected in grid |
Contact Fronius Service Partner. |
| 412 |
Fixed voltage mode selected instead of MPP mode |
If persists, contact Fronius Service Partner. |
| 415 |
Safety cut-out triggered via option card or REC ERBO |
If persists, contact Fronius Service Partner. |
| 416-419 |
Hardware/communication ID issues |
Usually firmware update required; if continues contact Fronius Service Partner. |
| 421 |
HID range error |
If persists, contact Fronius Service Partner. |
| 425-428 |
Communication fault / hardware fault |
Firmware update and if still persists contact Fronius Service Partner. |
| 431 |
Software fault |
Try AC reset (turn breaker off/on); if persists contact Fronius Service Partner. |
| 436-438 |
Functional incompatibility / PC board incompatibility |
Firmware update; if persists contact Fronius Service Partner. |
| 443 |
Intermediate circuit voltage too low or asymmetric |
If persists contact Fronius Service Partner. |
| 445 |
Invalid limit value settings |
Update firmware; if persists contact Fronius Service Partner. |
| 447 |
Insulation fault |
Contact installer / Fronius Service Partner. |
| 448 |
Neutral conductor not connected |
If persists contact Fronius Service Partner. |
| 450 |
Guard can’t be found |
If persists contact Fronius Service Partner. |
| 452 |
Memory/communication fault |
Contact installer / Fronius Service Partner. |
| 453 |
Power stage set & grid voltage not compatible |
Restart system and monitor; if persistent contact Fronius Service Partner. |
| 454 |
Power stage set & grid frequency not compatible |
Restart system; if persists contact Fronius Service Partner. |
| 456 |
Anti-islanding function no longer implemented correctly |
Restart and monitor; if persists contact Fronius Service Partner. |
| 457 |
Grid relay sticking or neutral conductor ground voltage too high |
Check grounding (< 30 V) and contact Fronius Service Partner. |
| 460-462 |
DSP reference voltage or monitoring routine fault |
Restart; if persists contact Fronius Service Partner. |
| 463 |
Reversed AC polarity |
Check AC connector; if persists contact Fronius Service Partner. |
| 474 |
RCMU sensor faulty |
Contact installer / Fronius Service Partner. |
| 475 |
Insulation fault / solar panel to ground fault |
Immediately contact installer / Fronius Service Partner. |
| 480-481 |
Functional incompatibility (PC boards) |
Firmware update; if persists contact Fronius Service Partner. |
| 482 |
Startup incomplete |
Perform full AC-reset; if persists contact Fronius Service Partner. |
| 483 |
UDC fixed voltage on MPP2 string out of limits |
Check MPP settings; if persists contact Fronius Service Partner. |
| 502 |
Insulation error on solar panels |
If persists, contact installer / Fronius Service Partner. |
| 509 |
No energy fed into grid in last 24 h |
Ensure grid/panel conditions fine; if persists for 2+ days contact Fronius Service Partner. |
| 515-516 |
Communication with filter/storage unit fault |
If persists, contact installer / Fronius Service Partner. |
| 517-523 |
PV strings low/no feed or communication fault |
Check ventilation, DC input, restart system; if persists contact Fronius Service Partner. |
| 560 |
Grid frequency too high causing derating |
Usually resolves automatically; monitor system and if frequent, contact Fronius Service Partner. |
| 601-609 |
CAN bus full, sensor faults, configuration out of limits |
Requires firmware, if persists contact Fronius Service Partner. |
| 700-794 |
Internal processor, USB, firmware update or memory fault codes |
If persists contact Fronius Service Partner. |
| 1001, 1024, 1030, 1112, 1175 |
(For GEN24 models) e.g. insulation measurement triggered, settings changed, grid frequency exceeded limit, low DC power |
Follow in-display advice; if unresolved contact installer / Fronius Service Partner. |